U125-2_KMC

U125-2_KMC

Primarily the undulator source U125-2 is designed and optimized for the UV energy range with most intense harmonics between 2 and 25 eV. On the other hand, the PHARAO experiment relies on hard x-rays, thus a typical energy window between 8 and 12 keV. Therefore the KMC branch makes use of the omnipresent, high energy wiggler part of the U125-2 undulator resulting in a remarkable peak brilliance of about 10^(12) ph/s/mm^2/mrad^2/0.1%BW at 10 keV.

Optical layout of the U125-2_KMC beamline

Optical layout of the U125-2_KMC beamline


Station data
Temperature range 280 - 1273 K
Pressure range UHV
Weitere Details PHARAO
Beamline data
Segment H03
Location (Pillar) 5.1
Source U125-2 (Undulator)
Monochromator KMC
Energy range 6 - 12 keV
Energy resolution 1500
Flux 109 cps
Polarisation horizontal
Divergence horizontal 0.8 mrad
Divergence vertical 0.08 mrad
Focus size (hor. x vert.) 0.5 mm x 0.5 mm
User endstation not possible
Distance Focus/last valve -- mm
Height Focus/floor level 1500 mm
Beam availability 12h/d
Phone --

For details and current status of the beamline please contact Michael Hanke hanke@pdi-berlin.de.